Parameters
Discriptio
*Application: suitable for busbar distribution cabinet;
*Features: primary current is more than 400 A, and the accuracy can reach 0.5.
Features
*Many types ,covering 20 - 160 mm busbar;
*can be used for larger secondary load;
*CE certified and RoHS compliant.
Drawing
TYPE |
Best input |
Size (mm) |
||||||
|
A |
L |
W |
H |
a |
e |
M |
N |
XH-KCT-23 |
100-400 |
90 |
40 |
110 |
22 |
32 |
48 |
52 |
XH-KCT-35 |
200-800 |
103 |
44 |
136 |
31 |
51 |
64 |
45 |
XH-KCT-58 |
200-1000 |
115 |
38 |
158 |
51 |
81 |
81 |
50 |
XH-KCT-88 |
200-1000 |
145 |
38 |
162 |
80 |
80 |
111 |
45 |
XH-KCT-812 |
500-1500 |
145 |
38 |
201 |
81 |
121 |
111 |
45 |
XH-KCT-310H |
500-3000 |
145 |
56 |
150 |
103 |
35 |
64 |
45 |
XH-KCT-610 |
800-3000 |
130 |
51 |
185 |
62 |
106 |
64.5 |
62 |
XH-KCT-410 |
800-4000 |
141 |
53 |
190 |
43 |
103 |
64.5 |
45 |
XH-KCT-816 |
1000-5000 |
185 |
53 |
248 |
82 |
161 |
119 |
45 |
Specs
Standard: GB/T 20840.1 and.2;
*Rated Voltage:0.4/0.66/0.69/0.72KV;
*Withstand Voltage: 2 / 3 KV;
*Rated Frequency: 50 / 60 HZ;
*Protection Class:Ip 20;
*Work environment: - 25℃ to 50℃。
Performance parameter
Model / |
Accuracy: 1.0 |
||||||||||||
100 |
200 |
300 |
400 |
500 |
600 |
800 |
1000 |
1500 |
2000 |
3000 |
4000 |
5000 |
|
XH-KCT-23 |
|
2.5VA | 2.5VA | ||||||||||
XH-KCT-35 |
2.5VA | 2.5VA | |||||||||||
XH-KCT-58 |
2.5VA | 2.5VA | 5VA | ||||||||||
XH-KCT-88 |
2.5VA | 2.5VA | 5VA | ||||||||||
XH-KCT-812 |
2.5VA | 2.5VA | 5VA | ||||||||||
XH-KCT-310 |
2.5VA | 5-10VA | |||||||||||
XH-KCT-610 |
5-10VA | ||||||||||||
XH-KCT-410 |
5-10VA | ||||||||||||
XH-KCT-816 |
5-20VA |
Installation
Ordering
1、Primary current( 1.2 - 1.5 times of rated working current, not more than 2 times);
2、Output current( input current of meter);
3、Second burden( Right secondary load can improve the accuracy of transformer);
4、Consider Size and spacing of busbar ,otherwise it cannot be installed.
Previous
None
MORE PRODUCTS

-Mobile website-
苏ICP备11016088号 Power by 300.cn
Copyright © 2020 Jiangyin Spark Electronic Technology Co., Ltd